Sinceda ihlabathi likhula ukusukela ngo-2004

Isinxibelelanisi esingu-600A T sokuQhawulwa koluhlu

  • 600A T  Deadbreak Connector

Inkcazo emfutshane:


Iinkcukacha Product

FAQ

Iimpawu zemveliso

Anhuang ezikhethekileyo Deadbreak Isinxibelelanisi, siya kubonelela kwizinga eliphezulu break breaker Connector.

Ukuphunyezwa kwemigangatho:

● Inkqubo yesinxibelelanisi esahluliweyo sokuhambisa iinkqubo zokuhambisa ngaphezulu; I-ANSI / IEEE Std386-2006600V

● Iibhatyi zesemiconductor eziveziweyo zeentambo zevolthi eziphezulu kunye nezihlanganisi ezinokuhlulwa zigqunyiwe;

● Iintambo zombane ezikhutshiweyo nezifakelweyo ngombane ongaphezulu kwe-1 kV (Um = 1.2 kV) ukuya kwi-30 kV (Um - 35 kV);

● Iindlela zokuvavanya izixhobo zombane ezinee-voltages ezilinganisiweyo ukusuka kwi-6 kV (Um = 7.2 kV) ukuya kwi-30 kV (Um = 35 kV);

● Iintambo zombane ezikhutshiweyo nezifakelweyo ngombane oqingqiwe ukusuka kwi-1 kV (Um = 1.2 kV) ukuya kwi-35 kV (Um = 40.5 kV).

● Ukulungelelanisa ukufakelwa kwamandla ombane kunye nokuhambisa izixhobo ze-GB / T4109-1999

● Ubume bobuchwephesha bamandla ombane aphezulu;

● Isinyithi esingenamikhala - ukuvalelwa kweoksidi;

● Iintambo zombane ezinee khonkco ezandisiweyo-Isahlulelo simisela ubukhulu bemikhono kunye nezinto zokulinganisa ezahlukileyo ze-Um ezantsi kwe-35 kV DIN 47636-7-1990.

I-15kV / 24kV 600A yeCandelo T Isinxibelelanisi sokuQhekeka sisetyenziselwa ukuphelisa intambo yombane ephezulu yangaphantsi komhlaba kwisiguquli, iswitshi, iswitsgear kunye nezinye izixhobo. Ikhuselwe ngokupheleleyo, ingaphantsi. Iinkqubo zethu zibonelela ngendawo ekhethekileyo yokuvavanya indawo yokuvavanya efanayo kumanqaku ovavanyo kwizidibanisi zengqiniba ezingama-200A. Oku kuvumela ukusetyenziswa kweeMpawu zeMpazamo. Izihlanganisi ze-T zibandakanya isinxibelelanisi seC T kunye nomthwalo wokuqhekeza umthwalo. Ikwabonelela ngendawo efanelekileyo yokubanjwa kwe-MOVE okanye ingqiniba yomhlaba. Bafumaneka kwicandelo lokuqhuba elingama-25-500m² ngentambo engama-24kV.

 

Amanqaku ombane aqhubekayo

Umba

Idatha ye-15kV

Idatha ye-25kV

Idatha ye-35kV

Umbane osebenzayo oqhubekayo

8.7kV / 14.4kV

15.2kV 26.3kV

26kV / 35kV

AC ukumelana ombane

45kV / 1min

55kV / 5min

117kV / 5min

DC ukumelana ombane

53kV / 15min

78kV / 15m kwi

104kV

1.5 / 50 μs Im pulse ene-voltage yokuma

95kV

125kV

215kV

Ukukhutshwa kwamandla ombane

13kV

22kV

45kV

 

Inqanaba langoku

Umba

200AMP

I-600AMP

Ukulayisha okusebenzayo

yangoku

Ifumaneka kwi-14.4kV kunye nama-200A amaxesha ali-10 ngaphantsi

ukusebenza kunye nokuvalwa

 

Icala livaliwe

yangoku

Ifumaneka kwi-14.4kV, 1000N0.175 1 ixesha elingaphantsi

ngephutha kuvaliwe ukusebenza

 

Uzinzo lobushushu

yangoku

16kA 1s

30kA 2s

Incopho ukumelana

yangoku

10kA

105kA

 img2222

Isalathiso No. Icandelo lokuwela lomqhubi (mm²) Uluhlu lwe-Stretch ngaphezulu kwe-insulation (mm)
AH TT 24 / 600-35

35

18.6

AH TT 24 / 600-50

50

19.6

AH TT 24 / 600-70

70

21

AH TT 24 / 600-95

95

22.6

AH TT 24 / 600-120

120

24.2

AH TT 24 / 600-150

150

25.6

AH TT 24 / 600-185

185

27.2

AH TT 24 / 600-240

240

28.7

AH TT 24 / 600-300

300

31.1

AH TT 24 / 600-400

400

33.2


  • Egqithileyo
  • Okulandelayo: