I-Anhuang igxile kwi-Deadbreak Connector, sinikezela nge-Dead break Connector ekumgangatho ophezulu.
● Inkqubo yokudibanisa egqunyiweyo eyahlulweyo kwiinkqubo zokusasaza ezingentla; ANSI / IEEE Std386-2006600V
● Iijakethi ze-semiconductor eziveziweyo zee-slices zekhebula ezine-voltage ephezulu kunye nezihlanganisi ezigqunyiweyo ezahlulweyo;
● Iintambo zamandla ezifakwe i-insulation ezikhutshiweyo kunye nezixhobo zazo ezine-voltages ezilinganisiweyo ezingaphezulu kwe-1 kV (Um = 1.2 kV) ukuya kwi-30 kV (Um – 35 kV);
● Iindlela zokuvavanya izixhobo zeentambo zombane ezineevolthi ezilinganisiweyo ukusuka kwi-6 kV (Um = 7.2 kV) ukuya kwi-30 kV (Um = 35 kV);
●Iintambo zamandla ezifakwe i-insulation ezikhutshiweyo kunye nezixhobo zazo ezine-voltage ezilinganisiweyo ukusuka kwi-1 kV(Um = 1.2 kV) ukuya kwi-35 kV (Um = 40.5 kV).
● Ukulungelelaniswa kokufakwa kwe-insulation kwezixhobo zokuhambisa nokuhambisa i-high-voltage GB/T4109-1999
● Imeko yobuchwepheshe ye-high-voltage bushing;
● Isinyithi esingenazikhewu – izinto zokuthintela ukuxinana kwe-oxide;
● Iintambo zombane ezineekhowuni zokwandisa – Iiseti zokwahlulahlula ubukhulu beemikhono kunye nezixhobo ezahlulweyo ze-Um ngaphantsi kwe-35 kV DIN 47636-7-1990.
I-15kV/24kV 600A Class T Deadbreak Connector isetyenziselwa ukuphelisa intambo engaphantsi komhlaba ene-voltage ephezulu ukuya kwiitransformer, iiswitshi, iiswitshi kunye nezinye izixhobo. Ikhuselwe ngokupheleleyo, iyakwazi ukuntywiliselwa emanzini. IiNkqubo zethu zibonelela ngendawo yokuvavanya ekhethekileyo efana neendawo zokuvavanya kwii-200A elbow connectors. Oku kuvumela ukusetyenziswa kweFault Indicators. Ii-T connectors ziquka i-T Cable Connector kunye ne-load break bushing extender. Zikwabonelela ngendawo efanelekileyo ye-MOVE arrester okanye i-grounding elbow. I-conductor cross section ifumaneka kwi-25-500m² yentambo ye-24kV.
| Into | Idatha ye-15kV | Idatha ye-25kV | Idatha ye-35kV |
| I-voltage yokusebenza eqhubekayo | 8.7kV/14.4kV | 15.2kV 26.3kV | 26kV/35kV |
| I-AC imelana ne-voltage | 45kV/1min | 55kV/5min | 117kV/5min |
| I-DC imelana nombane | 53kV/15min | 78kV/15m intshi | 104kV |
| I-1.5/50 μs I-pulse yam ine-voltage yokuma | 95kV | 125kV | 215kV |
| I-voltage yokukhupha inxalenye | 13kV | 22kV | 45kV |
| Into | 200AMP | I-600AMP |
| Ukusebenza komthwalo yangoku | Ifumaneka kwi-14.4kV kunye ne-200A amaxesha ali-10 ngaphantsi ukusebenza okuqhekezayo nokuvaliweyo |
|
| Impazamo ivaliwe yangoku | Ifumaneka kwi-14.4kV, 1000N0.175 ixesha eli-1 ngaphantsi ngokusebenza okuvaliweyo ngenxa yempazamo |
|
| Ubushushu obuzinzileyo yangoku | 16kA 1s | 30kA 2s |
| Ukumelana nencochoyi yangoku | 10kA | 105kA |

| Inombolo yesalathiso | Icandelo elinqamlezileyo lomqhubi (mm²) | Uluhlu lokwelula phezu kobushushu (mm) |
| AH TT 24/600-35 | 35 | 18.6 |
| AH TT 24/600-50 | 50 | 19.6 |
| AH TT 24/600-70 | 70 | 21 |
| AH TT 24/600-95 | 95 | 22.6 |
| AH TT 24/600-120 | 120 | 24.2 |
| AH TT 24/600-150 | 150 | 25.6 |
| AH TT 24/600-185 | 185 | 27.2 |
| AH TT 24/600-240 | 240 | 28.7 |
| AH TT 24/600-300 | 300 | 31.1 |
| I-AH TT 24/600-400 | 400 | 33.2 |