Isixhumi se-Deadbreak se-600A T
1. Yinto egqunywe ngokupheleleyo, evalwe ngokupheleleyo, echukumisekayo ngelixa inamandla.
2. Isetyenziswa kakhulu kwiitransformer zokusasaza zangaphandle, iitransformer zohlobo lwebhokisi yaseMelika, iiyunithi eziphambili zeringi, iibhokisi zesebe leentambo, iitransformer ezingaphantsi komhlaba kunye nezinye izixhobo zombane zokunxibelelana.
3. Isebenzisa i-EPDM (irabha ephindwe kathathu) yomgangatho ophezulu.
  • Iinkcukacha zeMveliso

  • Iithegi zeMveliso

I-Anhuang igxile kwi-Deadbreak Connector, sinikezela nge-Dead break Connector ekumgangatho ophezulu.

Ukuphunyezwa kwemigangatho:

● Inkqubo yokudibanisa egqunyiweyo eyahlulweyo kwiinkqubo zokusasaza ezingentla; ANSI / IEEE Std386-2006600V

● Iijakethi ze-semiconductor eziveziweyo zee-slices zekhebula ezine-voltage ephezulu kunye nezihlanganisi ezigqunyiweyo ezahlulweyo;

● Iintambo zamandla ezifakwe i-insulation ezikhutshiweyo kunye nezixhobo zazo ezine-voltages ezilinganisiweyo ezingaphezulu kwe-1 kV (Um = 1.2 kV) ukuya kwi-30 kV (Um – 35 kV);

● Iindlela zokuvavanya izixhobo zeentambo zombane ezineevolthi ezilinganisiweyo ukusuka kwi-6 kV (Um = 7.2 kV) ukuya kwi-30 kV (Um = 35 kV);

●Iintambo zamandla ezifakwe i-insulation ezikhutshiweyo kunye nezixhobo zazo ezine-voltage ezilinganisiweyo ukusuka kwi-1 kV(Um = 1.2 kV) ukuya kwi-35 kV (Um = 40.5 kV).

● Ukulungelelaniswa kokufakwa kwe-insulation kwezixhobo zokuhambisa nokuhambisa i-high-voltage GB/T4109-1999

● Imeko yobuchwepheshe ye-high-voltage bushing;

● Isinyithi esingenazikhewu – izinto zokuthintela ukuxinana kwe-oxide;

● Iintambo zombane ezineekhowuni zokwandisa – Iiseti zokwahlulahlula ubukhulu beemikhono kunye nezixhobo ezahlulweyo ze-Um ngaphantsi kwe-35 kV DIN 47636-7-1990.

I-15kV/24kV 600A Class T Deadbreak Connector isetyenziselwa ukuphelisa intambo engaphantsi komhlaba ene-voltage ephezulu ukuya kwiitransformer, iiswitshi, iiswitshi kunye nezinye izixhobo. Ikhuselwe ngokupheleleyo, iyakwazi ukuntywiliselwa emanzini. IiNkqubo zethu zibonelela ngendawo yokuvavanya ekhethekileyo efana neendawo zokuvavanya kwii-200A elbow connectors. Oku kuvumela ukusetyenziswa kweFault Indicators. Ii-T connectors ziquka i-T Cable Connector kunye ne-load break bushing extender. Zikwabonelela ngendawo efanelekileyo ye-MOVE arrester okanye i-grounding elbow. I-conductor cross section ifumaneka kwi-25-500m² yentambo ye-24kV.

 

Uvavanyo lwe-voltage oluqhubekayo

Into

Idatha ye-15kV

Idatha ye-25kV

Idatha ye-35kV

I-voltage yokusebenza eqhubekayo

8.7kV/14.4kV

15.2kV 26.3kV

26kV/35kV

I-AC imelana ne-voltage

45kV/1min

55kV/5min

117kV/5min

I-DC imelana nombane

53kV/15min

78kV/15m intshi

104kV

I-1.5/50 μs I-pulse yam ine-voltage yokuma

95kV

125kV

215kV

I-voltage yokukhupha inxalenye

13kV

22kV

45kV

 

Uvavanyo lwangoku

Into

200AMP

I-600AMP

Ukusebenza komthwalo

yangoku

Ifumaneka kwi-14.4kV kunye ne-200A amaxesha ali-10 ngaphantsi

ukusebenza okuqhekezayo nokuvaliweyo

 

Impazamo ivaliwe

yangoku

Ifumaneka kwi-14.4kV, 1000N0.175 ixesha eli-1 ngaphantsi

ngokusebenza okuvaliweyo ngenxa yempazamo

 

Ubushushu obuzinzileyo

yangoku

16kA 1s

30kA 2s

Ukumelana nencochoyi

yangoku

10kA

105kA

 img2222

Inombolo yesalathiso Icandelo elinqamlezileyo lomqhubi (mm²) Uluhlu lokwelula phezu kobushushu (mm)
AH TT 24/600-35

35

18.6

AH TT 24/600-50

50

19.6

AH TT 24/600-70

70

21

AH TT 24/600-95

95

22.6

AH TT 24/600-120

120

24.2

AH TT 24/600-150

150

25.6

AH TT 24/600-185

185

27.2

AH TT 24/600-240

240

28.7

AH TT 24/600-300

300

31.1

I-AH TT 24/600-400

400

33.2

Uphando

Ukuba unemibuzo malunga nekowuteshini okanye intsebenziswano, nceda ukhululeke ukusithumelela i-imeyile kule dilesiglobal@anhelec.comokanye sebenzisa le fomu ilandelayo yokubuza. Iintengiso zethu ziya kuqhagamshelana nawe zingadlulanga iiyure ezingama-24. Enkosi ngomdla wakho kwiimveliso zethu.