Sinceda ihlabathi likhula ukusukela ngo-2004

Iimveliso

  • Dropout Fuse YK2 Series

    Uthotho lokulahla iFuse YK2

    Ukucinywa ngokubanzi kweFuse Fuse luhlobo lwangaphandle lwamandla ombane aphezulu osasazo sombane okanye imigca yokuhambisa kwaye isetyenziselwa ikakhulu ukukhusela abaguquli okanye imigca ngokuchasene nefuthe eliphakanyiswe sisiphaluka esifutshane, ukulayisha ngaphezulu kunye nokutshintsha okwangoku. Ukucinywa kwefuse okushiyekileyo kwenziwa ngenkxaso yokwambathisa kunye nesiphatho sefuse, abafowunelwa abemileyo abathe nkqo kumacala amabini enkxaso yokwambathisa kunye nokuhambisa unxibelelwano olufakelwe kwiziphelo ezibini zesithwali sefuse. Ingaphakathi lesiphatho sefuse yindawo yokucima ...
  • vacuum interrupter

    isiphazamisi

    Isiphazamisi se-vacuum sisebenzisa i-ceramic yamaza njengegobolondo yokwambathisa, izinto zoqhakamshelwano yi-CuCr alloy, ulwakhiwo lwendebe yemagnethi ende, enesakhono sokuqhekeza, inqanaba eliphezulu lokufaka, amandla okucima i-arc, ubomi obude, ubungakanani obuncinci kunye nokugcinwa okulula, Akukho dubulo umngcipheko, akukho ungcoliseko, ingxolo ephantsi njalo njalo. Ipharamitha yobuchwephesha engundoqo Ixabiso elilinganisiweyo levolthi 12kV ikaliwe yangoku i-630A ilinganiswe rhoqo kwi-50Hz ilinganiswe ixesha elifutshane lamandla ombane ukumelana nevolthi (1 imiz) 42k ...
  • Dropout Fuse YK1 Series

    Ukulahla iFuse YK1 Series

    Ukucinywa ngokubanzi kweFuse Fuse luhlobo lwamandla ombane aphezulu asesiguquli sokuhambisa okanye imigca yokuhambisa kwaye isetyenziselwa ikakhulu ukukhusela abaguquli okanye imigca ngokuchasene nefuthe eliphakanyiswe sisiphaluka esifutshane, ukulayisha ngaphezulu kunye nokutshintsha okwangoku. Ukucinywa kwefuse okushiyekileyo kwenziwa ngenkxaso yokwambathisa kunye nesiphatho sefuse, abafowunelwa abemileyo abathe nkqo kumacala amabini enkxaso yokwambathisa kunye nokuhambisa unxibelelwano olufakwe kwiziphelo ezibini zesithwali sefuse. Ingaphakathi lesiphatho se fuse lucimi ...
  • Indoor SF6 for switchgear 10KV 630A Gas Insulated Load Break Switch LBS Indoor Isolating switch

    I-SF6 yangaphakathi yokutshintsha i-10KV 630A yeGesi yokuGcina iMithambo yokuGqithisa i-LBS ngaphakathi

    Ukusetyenziswa kweemeko zokusingqongileyo: 1. Ukuphakama: ≤2000m; Ubunzulu benyikima: hayi ngaphezulu kwesibhozo. Ubushushu bomoya: abukho ngaphezulu kwe + 40 ℃, hayi ngaphantsi kwe -30 ℃. Umndilili wemihla ngemihla wokufuma okumalunga nama-90%, umndilili wenyanga ongekho ngaphezulu kwe-90%. 3. Indawo yofakelo enobungqingili rhoqo kunye nobundlobongela ayilungelanga indawo yofakelo enomphunga wamanzi, igesi, ukufakwa kweekhemikhali, ityuwa yokutshiza, uthuli kunye nokungcola, umlilo kunye neengozi zokuqhuma ngokucacileyo ezichaphazela ...
  • Incoming operating mechanism for gas insulated switchgear

    Inkqubo yokusebenza engenayo yokutshintsha igesi xa igqunyiwe

    I-SF6 i-switchgear switchgear eyongezwayo: Isikhokelo / iMoto: A, ukudibanisa okunzima / B, ukuthamba okuthambileyo Iiparamitha zobuchwephesha: Isiqulatho seParameter yokuTshintsha umlinganiso woxinzelelo loqhagamshelwano N 190-210 Vula isigaba sesithathu esingafaniyo ms Close2 Vala isigaba sesithathu esingafaniyo ms ≤2 Umndilili wokuvula Isantya m / s 3-6 Ukuvala umndilili wesantya m / s 4-6 Isigaba sesithathu sokuxhuzula umgangatho m / s ≤2 Isigaba esithathu sokuphuma kwe-engile ° 88 ° Ubomi boomatshini Amaxesha e-10000 amandla okuSebenza N -110 Ukuzoba:
  • outgoing mechanism

    indlela ephumayo

    I-SF6 i-switchgear switchgear eyongezwayo: Incwadi yesikhokelo / iMoto: A, i-hard interlock / B, ukuthamba okuthambileyo Iiparamitha zobuchwephesha: Isiqulatho seYunithi Ipharamitha Shintsha uqhagamshelo kumgangatho woxinzelelo N 80-190 Vula isigaba sesithathu esingafaniyo ms Close2 Vala isigaba sesithathu esingafaniyo ms ≤2 Umndilili wokuvula Isantya m / s 3-6 Ukuvala umndilili wesantya m / s 4-6 Isigaba sesithathu sokuxhuzula umgangatho m / s ≤2 Isigaba esithathu sokuphuma kwe-engile ° 88 ° Ubomi boomatshini Amaxesha e-10000 amandla okuSebenza N -110 Ukuzoba:
  • 12kV 630A loadbreak switch

    12kV 630A switchbreak utshintsho

    Iparamitha zobuchwephesha I-12KV yeCandelo lokuQinisekayo Ipharamitha ilinganiselwe iVoltage KV 12 Ukulinganiswa kwamaxesha ombane HZ 50 Imali eqingqiweyo I-630 ilinganisiwe isekethe emfutshane yokumelana ne-cu-rent KA KA-20/25 Kukalwe ukuphakama okumiselweyo ngoku Ixesha 10000 I-triphase evulekileyo engafaniyo ms ≤2 Ukuvala i-triphase ngokungafaniyo ms ≤2 Ukuvula isantya esiphakathi ngesantya se-3-6 Ukuvala i-avareji yesantya m / s 4-6 Ukusebenza kwenyathelo lokophuka koxinzelelo lomoya: 22KV -28 ...
  • SF6 Insulated Load Break Switch

    SF6 igqunyiwe Load Break Break Tshintsha

    Amagqabantshintshi Umtshintshi womthwalo luhlobo lwesitshintshi kunye nesixhobo sokucima iarc elula. Isebenzisa i-SF6 igesi njengokugquma kunye nokucima i-arc. Ingasetyenziselwa ukuvala kunye nokwaphula umthwalo wangoku kunye nokulayisha ngoku ngaphezulu. Ingasetyenziselwa ukuvala kunye nokwaphula umthwalo. Imigca, akukho mthwalo wokuguqula kunye neebhanki ze-capacitor, njl., Zonke izinto ezithathu zokulayisha umthwalo kunye nemisebenzi yokucima kunye nokucima ilula kubume kwaye ifikeleleka. Ukongeza kubomi obude, ukophuka okuqinileyo ...
  • 35kV Oil-immersed two-position loadbreak switch
  • Oil-immersed four-position loadbreak switch

    Ioyile-emanzini indawo yokulayita yokutshintsha indawo

    I-12kV 630A i-oyile egcwalise indawo-ezine yokutshintsha umthwalo yenzelwe i-ring-type US-box ring ring change cabinet eyenzelwe ukuhlangabezana ne-IEEE, IEC kunye ne-GB yemigangatho yazo zonke iimfuno. Ingasetyenziselwa kwiinkqubo ezisisiseko okanye zangaphantsi komhlaba. Ukuntywiliselwa kwesikhundla sokulayisha ioyile esine kwindawo yokufaka, kufutshane nesiseko sombane kunokunciphisa uqhagamshelo lwangaphakathi lweCable capacitance, kwaye ke kunciphise ngokubonakalayo iluphu kwi-ferromagnetic resonance. Omabini amacala okunyusa kunye nokunyuka okuphezulu kuyafumaneka ngokubanzi ...
  • Oil-immersed two-position loadbreak switch

    I-oyile-emanzini indawo yokulayisha umthwalo

    Ioyile-emanzini indawo yokubeka umthwalo wokucoca ulwelwesi kusetyenziswa ubukhulu becala kutshintsho lwebhokisi yaseMelika, kunye nendlela yokusebenza yasentwasahlobo, sisigaba sesithathu sokudibanisa ukugqibezela umsebenzi wokuqhekeza kunye nokuvala umsebenzi. Ngamajelo amabini okulayisha umthwalo anokuphinda abunjwe ngenkqubo yokutshintshela uhlobo lwenkqubo yokuhanjiswa kwempahla, indawo ezimbini zokutshintsha: kuvuliwe, kucinyiwe. Ukulinganiswa kwe-10kV kunokusetyenziselwa iiprojekthi zamandla omoya ekusebenziseni iinguqu. Ngaphambi kokusetyenziswa kwesiguquli kufuneka somiswe. M ...
  • XRNT backup fuse

    I-fuse yokugcina i-XRNT

    Isiphazamisi se-magne X sisetyenziswa kuthotho lwezixhobo ezikhuselekileyo zangoku zokukhusela ezinje nge-Bay-o-net Fuse okanye iMagne X Isiphazamisi se-magne X. Umatshini ophazamisayo ongu-Magne X osebenza ngoku onciphisa isiphumo sempazamo ephezulu yoxinzelelo kwizixhobo nakwinkqubo yokuhambisa. Ubuncinci bokuphazanyiswa kokulinganiswa buhambelana naleyo yokuphazamisa okwangoku ukuthintela ukusebenza okungafunekiyo okwangoku; kodwa ukuphakama kokuphakama okuphezulu kuya kucoca okuphezulu ...