FZN25-12RD/T630-20
Isishwankathelo:
I-FZN25 kunye ne-FZRN25 yokutshintsha komthwalo we-vacuum kunye nezixhobo zombane ezidibeneyo zifanelekile kwinqanaba lesithathu i-AC 50Hz inethiwekhi yendandatho okanye unikezelo lwamandla ombane kunye nezixhobo zombane zombane zokulawula umthwalo kunye nokukhusela i-short-circuit. Ukutshintsha komthwalo ovulekileyo kunye nokuvala imithwalo, i-current-loop current, kunye ne-no-load transformers. kunye nentambo yokutshaja yangoku. Isixhobo sombane esidityanisiweyo sinokwaphula nawuphi na umsinga ukuya kuthi ga kwireyithingi yangoku emfutshane, kwaye samkele ikhefu lokuzihlukanisa elisebenza ngokuthe ngqo kunye nonxibelelwano kunye negumbi lokucima i-arc yevacuum. Ifumaneka kwimisebenzi yezandla kunye nombane.
I-FZN25 kunye ne-FZRN25 yokutshintsha komthwalo we-vacuum kunye nezixhobo zombane ezidibeneyo zinokuqonda ixesha elilodwa lokuphuka kwe-arc kunye ne-arc yokucima i-chamber fracture.
I-FZN25 kunye ne-FZRN25 yokutshintsha komthwalo we-vacuum kunye nezixhobo zombane ezidibeneyo zinokumelana nokushisa okuphezulu, ukugquma okuqinileyo, kunye ne-flame-retardant transparent glass covers phakathi koqhagamshelwano olusisigxina kunye ne-cylinder ehambayo ehambayo, eqinisekisa ngokufanelekileyo ukusebenza ngokukhuselekileyo kwezixhobo kunye nokhuseleko lomntu. Ukutshintshwa komthwalo kunye nokutshintshwa komhlaba kuxhotywe ngokudibanisa okuthembekileyo komatshini, okungaqinisekisi kuphela ukhuseleko kodwa kuququzelele ukugcinwa.
Idatha yobugcisa:
| Umbane olinganisiweyo | 12KV |
| Ilinganiswe rhoqo | 50Hz |
| Ikalwe ngoku | 630A |
| 1 minamandla ombane ukumelana nombane | 30KV, 42KV, 48KV |
| Impembelelo yombane imelana nombane | 75kv, 85kv |
| Incopho elinganisiweyo ukumelana yangoku | 50KA |
| Ilinganiswe ngomthwalo osebenzayo wesekethe evulekileyo | 630A |
| Ilinganiswe ngokuvaliweyo-loop evulekileyo yesekethe yangoku | 630A |
Imeko yokusingqongileyo:
1.Umda ophezulu weqondo lokushisa lomoya: +40 ° C, umda ophantsi: -10 ° C;
2. Umphakamo: ≤ l000m;
3. Umyinge wemihla ngemihla womswakama ohambelanayo ngu ≤ 95%, kwaye umyinge wenyanga ngu ≤ 90%;
4. Ukuqina kwenyikima akudluli kwiidigri ezi-8;
5. Iindawo ezingenamlilo, ingozi yogqabhuko-dubulo, umhlwa weekhemikhali kunye nokungcangcazela okukhulu;
6. Umoya ojikelezileyo akufanele ungcoliswe kakhulu ngeegesi ezivuthayo okanye ezinokutsha kunye nomphunga wamanzi.
Ulwazi lweodolo
1.Imodeli, igama, ubungakanani
2.Indlela yokusebenza
I-3.I-voltage elinganisiweyo, yangoku
I-4.I-voltage elinganisiweyo yendlela yokusebenza
5.Ngephaneli okanye ngaphandle kwayo
6.Nge okanye ngaphandle kokutshintsha komhlaba
7.Ukuba i-fuse iyafuneka, nikezela nge-fuse current rating